Pages

Showing posts with label AppV OSD script run procedure. Show all posts
Showing posts with label AppV OSD script run procedure. Show all posts

Thursday 21 June 2012

How OSD script runs


How the script runs


The new TIMEOUT attribute determines the following:
  • Whether the App-V (SoftGrid) client waits for the script to finish
  • The period that the App-V (SoftGrid) client will wait for the script to finish
For backward compatibility, the WAIT attribute is still supported in Microsoft App-V 4.x and in Microsoft SoftGrid 4.x

Set these attributes as follows:
    TIMEOUT
    • TIMEOUT=x
      The client will wait x seconds for the script to finish before the client returns an error.
    • TIMEOUT=0
      The client will wait indefinitely for the script to finish.

    WAIT
    • Wait=False
      The client will continue without waiting for the script to finish.
    • Wait=True
      The client will not start the next step until the script finishes.
Notes
  • The client does not support a pre-shutdown event. You cannot determine the exact moment at which a user will perform a shutdown. For example, you cannot predict when the user will clickClose or when the user will press ALT+F4.
  • You can use scripts in any language. However, the language must be installed locally on the client computer.